Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Genomics Inform ; 21(2): e24, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37704210

RESUMO

Assays of clinical diagnosis and species identification using molecular markers are performed according to a quantitative method in consideration of sensitivity, cost, speed, convenience, and specificity. However, typical polymerase chain reaction (PCR) assay is difficult to quantify and have various limitations. In addition, to perform quantitative analysis with the quantitative real-time PCR (qRT-PCR) equipment, a standard curve or normalization using reference genes is essential. Within the last a decade, previous studies have reported that the digital PCR (dPCR) assay, a third-generation PCR, can be applied in various fields by overcoming the shortcomings of typical PCR and qRT-PCR assays. We selected Stilla Naica System (Stilla Technologies), Droplet Digital PCR Technology (Bio-Rad), and Lab on an Array Digital Real-Time PCR analyzer system (OPTOLANE) for comparative analysis among the various droplet digital PCR platforms currently in use commercially. Our previous study discovered a molecular marker that can distinguish Hanwoo species (Korean native cattle) using Hanwoo-specific genomic structural variation. Here, we report the pros and cons of the operation of each dPCR platform from various perspectives using this species identification marker. In conclusion, we hope that this study will help researchers to select suitable dPCR platforms according to their purpose and resources.

2.
Genes Genomics ; 44(5): 617-628, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35353341

RESUMO

BACKGROUND: Since COVID-19 was declared the pandemic by the WHO, it has continued to spread. There is a need for rapid, efficient, and accurate diagnostic kits and techniques to control its spread. OBJECTIVE: The diagnostic capability of the qRT-PCR-based Real-Q 2019-nCoV Detection Kit and dPCR-based Dr. PCR™ Di20K COVID-19 Detection Kit was compared and evaluated. METHODS: Diagnostic tests for COVID-19 were performed using two different COVID-19 kits and 301 individual specimens with confirmed COVID-19 positive/negative at the government-accredited medical institution. Assessment of diagnostic capability was measured through diagnostic sensitivity, specificity, Cohen's Kappa coefficient, and dilutional linearity tests. RESULTS: The COVID-19 diagnostic test results using two kits and 301 individual specimens perfectly matched the pre-diagnosis results of the medical institution. In addition, the measurement results of diagnostic sensitivity and specificity were "1", indicating high diagnostic capability. Cohen's Kappa coefficient value is "1", which means that the diagnosis concordance between the two kits is "Almost Perfect". As a result of dilutional linearity tests to evaluate their detection capability, both kits were measured with very high detection reliability. CONCLUSION: Here, we propose that the dPCR-based Dr. PCR™ Di20K COVID-19 Detection Kit has the advantages of the dPCR method reported in the previous study and is suitable for point-of-care testing (POCT) by overcoming the limitations of space, test time, cross-over contamination, and biosafety due to omitting RNA extraction process.


Assuntos
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , Reação em Cadeia da Polimerase , RNA Viral/análise , RNA Viral/genética , Reprodutibilidade dos Testes , SARS-CoV-2/genética
3.
Genomics Inform ; 19(3): e34, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34638181

RESUMO

Digital PCR (dPCR) is the third-generation PCR that enables real-time absolute quantification without reference materials. Recently, global diagnosis companies have developed new dPCR equipment. In line with the development, the Lab On An Array (LOAA) dPCR analyzer (Optolane) was launched last year. The LOAA dPCR is a semiconductor chip-based separation PCR type equipment. The LOAA dPCR includes Micro Electro Mechanical System that can be injected by partitioning the target gene into 56 to 20,000 wells. The amount of target gene per wells is digitized to 0 or 1 as the number of well gradually increases to 20,000 wells because its principle follows Poisson distribution, which allows the LOAA dPCR to perform precise absolute quantification. LOAA determined region of interest first prior to dPCR operation. To exclude invalid wells for the quantification, the LOAA dPCR has applied various filtering methods using brightness, slope, baseline, and noise filters. As the coronavirus disease 2019 has now spread around the world, needs for diagnostic equipment of point of care testing (POCT) are increasing. The LOAA dPCR is expected to be suitable for POCT diagnosis due to its compact size and high accuracy. Here, we describe the quantitative principle of the LOAA dPCR and suggest that it can be applied to various fields.

4.
Genes Genomics ; 43(11): 1277-1288, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34524612

RESUMO

BACKGROUND: Coronavirus disease of 2019 (COVID-19) is well known as a fatal disease, first discovered at Wuhan in China, ranging from mild to death, such as shortness of breath and fever. Early diagnosis of COVID-19 is a crucial point in preventing global prevalence. OBJECTIVE: We aimed to evaluate the diagnostic competency and efficiency with the Allplex™ 2019-nCoV Assay kit and the Dr. PCR 20 K COVID-19 Detection kit, designed based on the qRT-PCR and dPCR technologies, respectively. METHODS: A total of 30 negative and 20 COVID-19 positive specimens were assigned to the diagnostic test by using different COVID-19 diagnosis kits. Diagnostic accuracy was measured by statistical testing with sensitivity, specificity, and co-efficiency calculations. RESULTS: Comparing both diagnostic kits, we confirmed that the diagnostic results of 30 negative and 20 positive cases were the same pre-diagnostic results. The diagnostic statistics test results were perfectly matched with value (1). Cohen's Kappa coefficient was demonstrated that the given kits in two different ways were "almost perfect" with value (1). In evaluating the detection capability, the dilutional linearity experiments substantiate that the Dr. PCR 20 K COVID-19 Detection kit could detect SARS-CoV-2 viral load at a concentration ten times lower than that of the Allplex™ 2019-nCoV Assay kit. CONCLUSIONS: In this study, we propose that the dPCR diagnosis using LOAA dPCR could be a powerful method for COVID-19 point-of-care tests requiring immediate diagnosis in a limited time and space through the advantages of relatively low sample concentration and small equipment size compared to conventional qRT-PCR.


Assuntos
Teste de Ácido Nucleico para COVID-19/métodos , Reação em Cadeia da Polimerase/métodos , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , SARS-CoV-2/isolamento & purificação , COVID-19 , Genes Virais/genética , Humanos , República da Coreia , SARS-CoV-2/genética , Sensibilidade e Especificidade , Carga Viral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...